Schmid Watson Installationsanleitung Seite 70

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 129
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 69
SZ-DOC-W5-1.pdf LTU/NTU
Version: 1.5 Operating Manual
61 Revision: 2002-09-10
UIF: Set the user interface type to E1 or PRA.
DSL Interface
POWER: Set remote powering on / off.
MASTER: Set DSL master mode / slave mode.
BACKOFF: Set power back-off on / off.
RESTART: Set autorestart on / off.
BACKOFF: Set SHDSL Power Back-Off function on / off.
TS / LINERATE: Set line rate:
LINERATE n i a
n denotes the number of DSL time slots to be transmitted,
i = 1 denotes the Z-bits automatically used to increase the EOC
bandwidth of about 3.2 kbit/s by 8 kbit/s and
a = 1 denotes asymmetric PSD operation.
Default i =1
Note: i = 0 or 1; 3 n 36
Note: This command is no longer supported from SW-Version 1.4 and
follows. Use TS command instead.
MODE: Select DSL operating mode:
MODE 1: 1 pair operation
MODE 2: 2 pair operation
MODE 3: 3 pair operation
MODE 4: 4 pair operation
Seitenansicht 69
1 2 ... 65 66 67 68 69 70 71 72 73 74 75 ... 128 129

Kommentare zu diesen Handbüchern

Keine Kommentare